摘    要:根据室内消火栓给水系统的构成要素,并结合GB 50016-2006建筑设计防火规范、GB 50045-95高层民用建筑设计防火规范(2005年版),对高层及多层消火栓给水系统进行了分析对比,并且对多层建筑的消火栓给水系统形式和范围进行了详细说明,以指导实践。

关 键 词:消防水池  消防水泵  消防水箱  消防增压泵

On differences of hydrant water supply system in multi-storey and high-rise buildings
LI Mao. On differences of hydrant water supply system in multi-storey and high-rise buildings[J]. Shanxi Architecture, 2011, 37(22): 136-137
Authors:LI Mao
Abstract:According to the components for the indoor hydrant water supply system,the paper combining with GB 50016-2006 the Fire-fighting Regulation for Architectural Design,GB 50045-95 the Design Regulation for High-rise Civil Buildings(Edition of 2005),analyzes and compares the differences of hydrant water supply system in multi-storey and high-rise buildings,and indicates the forms and scopes of the hydrant water supply system in multi-storey buildings,so as to direct the practice.