关 键 词:循环水  Fe含量  Cu含量  控制指标  腐蚀

AN APPROACH TO CONTROL INDEX OF Cu AND Fe CONTENT IN CIRCULATING WATER OF THERMAL POWER PLANTS
HUANG Shanfeng,LUO Jianghe,REN Zhigang,JIAO Huiliang,ZHANG Baoshan. AN APPROACH TO CONTROL INDEX OF Cu AND Fe CONTENT IN CIRCULATING WATER OF THERMAL POWER PLANTS[J]. Thermal Power Generation, 2010, 39(4). DOI: 10.3969/j.issn.1002-3364.2010.04.017
Authors:HUANG Shanfeng  LUO Jianghe  REN Zhigang  JIAO Huiliang  ZHANG Baoshan
Affiliation:HUANG Shanfeng1,LUO Jianghe1,REN Zhigang2,JIAO Huiliang3,ZHANG Baoshan31.Xi'an Thermal Power Research Institute Co Ltd,Xi'an 710032,Shaanxi Province,PRC2.Xi'an Inspection , Detection Institute of Special Equipments,X'an 710068,PRC3.Huaneng Shang'an Power Plant,Jingxing 050310,Hebei Province,PRC
Abstract:The forms and features of existing Cu and Fe in circulating water have been analysed,and a method for determining the control index of Cu and Fe content in circulating water through metal corrosion rate of Cu and Fe obtained from dynamic simulation test being put forward.The theoritical calculation and measurement in the field show that:(1) the reflection of corrosion rate of carbon steel by using Fe content in circulation water isn't obvious due to the solubility of iron corrosion products and protective f...