摘    要:采用控制电缆屏蔽层一端或二端接地的方式,对其屏蔽电磁场原理进行了分析并比较效果,并通过采用改进接地方式、加强隔离措施及改善电缆屏蔽等方法的有效结合,使变电所设备的电磁兼容能力得到明显提高,保证了变电所对牵引网的安全供电。

关 键 词:牵引变电所  电磁干扰  控制电缆  屏蔽层

On the measures to anti-electromagnetic interference of traction substation
ZHANG Guo-peng.On the measures to anti-electromagnetic interference of traction substation[J].Shanxi Architecture,2010,36(12):180-182.
Authors:ZHANG Guo-peng
Affiliation:ZHANG Guo-peng
Abstract:Adopting the way of using the control cable shield grounded at one or two ways,this paper analyzes and compares its shielding electromagnetic field theory.And by means of effective integration,such as improved grounding,strengthen the quarantine measures and improved cable shield.As a result,electromagnetic compatibility of substation equipment has been notably enhanced,ensuring the security of traction substation for power supply.