首页 | 本学科首页   官方微博 | 高级检索  
     


Crawlspace heating system in detached house with insulated foundation
Authors:Qing-rong Liu   Ying-jun Ruan   Yu-ji Ryu  Jian-xing Ren
Affiliation:[1]Institute of Energy and Environmental Engineering, Shanghai University of Electric Power, Shanghai 200090, China [2]School of Mechanical Engineering, Tongji University, Shanghai 200092, China; [3]Faculty of Environment Engineering, The University of Kitakyushu, Kitakyushu 808-0135, Japan
Abstract:Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Based on the field study result, by using the simulation software, THERB, the effectiveness of the crawlspace warm air heating system has been examined. The effect of the factors, such as the wind amount circulating between crawlspace and indoor space, foundation insulation condition, and heat amount into the crawlspace, on the indoor thermal environment has been analyzed. Based on these analyses, the measured crawlspace heating system can make the average temperature of the living room above 20 °C. These two houses have excellent thermal environment. According to the simulating result, heat amount input into crawlspace, which can make comfortable indoor thermal environment, for every month in heating period has been roughly concluded, and they are 600 W in December and March and 800 W in February and January, respectively.
Keywords:erawlspaee heating system  indoor thermal environment  detached house  floor insulation  foundation insulation
本文献已被 维普 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号