首页 | 本学科首页   官方微博 | 高级检索  
     

激光诱导击穿光谱设备在线冰铜成分检测应用进展
引用本文:潘从元,赵荣升,徐勇,张志国,王腾飞,金泽志. 激光诱导击穿光谱设备在线冰铜成分检测应用进展[J]. 冶金分析, 2021, 41(1): 41-46. DOI: 10.13228/j.boyuan.issn1000-7571.011188
作者姓名:潘从元  赵荣升  徐勇  张志国  王腾飞  金泽志
作者单位:1.合肥金星机电科技发展有限公司,安徽合肥 230088; 2.铜陵有色金属集团股份有限公司金冠铜业分公司,安徽铜陵 244100; 3.工业图像处理与分析安徽省重点实验室,安徽合肥 230088
基金项目:2019年合肥市借转补关键技术重大研发类项目(J2019G13)
摘    要:利用自主研发的基于激光诱导击穿光谱(LIBS)技术的激光成分分析仪对铜冶炼现场冰铜固体和熔体成分进行了在线检测,并与取样制样后实验室的X射线荧光光谱(XRF)检测结果进行了对比.分析数据为研发设备现场投用后具备对比数据的1 294炉次,包括878炉次固体冰铜和416炉次熔体冰铜.LIBS设备在线检测与取样制样后固体XR...

关 键 词:激光诱导击穿光谱(LIBS)  冰铜  在线检测  熔体  现场运行状况
收稿时间:2020-06-03

Application progress of online composition analysis of matte by laser-induced breakdown spectroscopy
PAN Congyuan,ZHAO Rongsheng,XU YongZHANG Zhiguo,WANG Tengfei,JIN Zezhi. Application progress of online composition analysis of matte by laser-induced breakdown spectroscopy[J]. Metallurgical Analysis, 2021, 41(1): 41-46. DOI: 10.13228/j.boyuan.issn1000-7571.011188
Authors:PAN Congyuan  ZHAO Rongsheng  XU YongZHANG Zhiguo  WANG Tengfei  JIN Zezhi
Affiliation:1. Hefei Jinxing Electromechanical Technology Development Co.,Ltd.,Hefei 230088,China; 2. Jinguan Copper Branch of Tongling Nonferrous Metals Group Co.,Ltd.,Tongling 244100,China; 3. Anhui Province Key Laboratory of Industrial Image & Analysis,Hefei 230088,China
Abstract:An independently-developed laser composition analyzer based on laser-induced breakdown spectroscopy (LIBS) technology was used to realize online detection of matte,both solid and molten matte.The tested results were compared with the X-ray fluorescence spectrometry(XRF) detection results with standard sample preparation.A total of 1 294 times with comparative data after the LIBS equipment was put into operation on site.The data consisted of 878 times solid matte and 416 times melt matte.Compared with the XRF detection results after sampling,the online detection of LIBS equipment had an average absolute error of 0.61%,and an average relative error of 1.1%.The online detection performance of the LIBS equipment had been tested,the average value of the detection result range during the copper extraction process of the same furnace was 0.64%,and the average minimum error of the online detection results compared with XRF sampling test result was 0.32%.The results showed that the LIBS technology could achieve reliable online measurement of matte in different states,and its performance met the real-time and reliability requirements of the production process for element detection.The application of LIBS equipment realized the stable and reliable online detection of the melt composition in the smelting process of the metallurgical industry,which could provide the necessary foundation for fine control of the smelting production process,the metal balance optimization and information management.
Keywords:laser-induced breakdown spectroscopy(LIBS)  matte  online detection  molten  on-site operating condition  
本文献已被 CNKI 等数据库收录!
点击此处可从《冶金分析》浏览原始摘要信息
点击此处可从《冶金分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号