Process Control For Ozonation Systems: A Novel Real-Time Approach
Authors:Hans-Peter Kaiser  Oliver Köster  Markus Gresch  Philipp MJ Périsset  Pascal Jäggi  Elisabeth Salhi
Affiliation:1. Zurich Water Works , 8021 , Zurich , Switzerland;2. Hunziker Betatech AG , 8411 Winterthur, Switzerland;3. Eawag, Swiss Federal Institute of Aquatic Science and Technology , 8600 , Dübendorf , Switzerland;4. Eawag, Swiss Federal Institute of Aquatic Science and Technology , 8600 , Dübendorf , Switzerland;5. Eawag, Swiss Federal Institute of Aquatic Science and Technology , 8600 , Dübendorf , Switzerland;6. Amt für Umwelt , CH-4509 , Solothurn , Switzerland
Abstract:For real-time control of ozonation processes in water works, a sequencing batch reactor was constructed to measure the ozone decay rate constant (kO3) in short time intervals of about 15 min. The batch reactor is filled during the production process, immediately after dissolving ozone in water by a static mixer. On the basis of kO3 and the initial ozone concentration (O3]0), and the experimentally determined ratio of the concentrations of ?OH radicals to ozone (Rct), the degradation of micropollutants in ozone reactors (modeled as Continuously Stirred Tank Reactors - CSTRs) were calculated for compounds with known reaction rate constants with ozone and ?OH radicals. Calculated degradation of atrazine, iopromide, benzotriazole and acesulfame are in good agreement with measured data. For acesulfame the following rate constants were determined in this study at 20 oC: reaction rate constant with ozone = 88 M?1s?1, reaction rate constant with ?OH radical = 4.55?×?109 M?1s?1. For the ozone reaction an activation energy of 35 kJ/mol was determined. Similarly to micropollutants, the relative inactivation of microorganisms (N/N0) can be calculated based on the inactivation rate constant for ozone and if applicable the lag phase. The pI-value (=??logN/N0) was introduced and implemented in the process management system to calculate online the log inactivation of reference microorganisms such as B. subtilis spores. The system was tested for variation of pH (6.5–8.5), DOC (1.2–4.2 mg/L) flowrate 3.2–12 m3/h and temperature (5.7–9 oC). Furthermore, a given pI-value, e.g. 1 for a 1-log inactivation of B. subtilis spores, can be set as control parameter in the process management system. The ozone gas flow is then adjusted until the set pI-value is reached. The process control concept was validated with B. subtilis spores. Generally, a good agreement was found between calculated and measured inactivation data. It was also demonstrated, that a constant ozone residual may lead to insufficient disinfection or overdosing of ozone. The new process control concept for ozonations based on onsite measurement of the ozone decay rate constant and the pI-value allows to assess disinfection and degradation processes quantitatively in real-time.
Keywords:Ozone  Second-Order Rate Constants  Acesulfame  Ozone Decay Rate Constant  Degradation of Micropollutants  Disinfection  Bacillus Subtilis Spores  Reactor Hydraulics  Process Management System  Process Control
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号