广州地区某建筑群典型建筑能耗模拟及分析 |
| |
引用本文: | 江向阳,张勇华.广州地区某建筑群典型建筑能耗模拟及分析[J].广州建筑,2011,39(5):43-48. |
| |
作者姓名: | 江向阳 张勇华 |
| |
作者单位: | 1. 广州市建筑科学研究院有限公司,广州,510440 2. 广州大学土木工程学院,广州,510006 |
| |
摘 要: | 本文运用eQUEST软件对广州地区某建筑群内典型建筑进行能耗模拟计算.计算两栋典型建筑的节能率。计算结果表明,通过强化建筑自然通风降温功能,提高围护结构隔热性能和提高空调设备能效比等节能措施,A1建筑和B1建筑节能率分别为69.7%和64.8%。该建筑群的节能设计优于《夏热冬暖地区建筑节能设计标准》JGJ75—2003...
|
关 键 词: | eQUEST 节能率 能耗模拟 |
Building Energy Simulation and Analysis for A Building Group in Guangzhou |
| |
Authors: | JIANG Xiang-yang ZHANG Yong-hua |
| |
Affiliation: | 1.Guangzhou Institute of Building Science Co.,Ltd., Guangzhou 510440) (2.College of Civil Engineering Guangzhou University, Guangzhou 510006) |
| |
Abstract: | In this paper, the software of eQUEST is used to simulate energy consumption for two typical buildings in building group in Guangzhou, by which two typical buildings energy-saving rates are obtained. Simulation results show that through enhanced natural ventilation, improved thermal performance of envelope and improved EER of air conditioning system, the energy-saving rates of building A1 and building B1 are 69.7% and 64.8% respectively. The building energy efficiency design is superior to《Residential building energy efficiency design standard in hot summer and warm winter zone》 JGJ 75-2003. It plays an exemplary role in progressively implementing the design stan- dard of energy-saving 65% in Guangzhou. |
| |
Keywords: | eQUEST energy-saving rate energy simulation |
本文献已被 CNKI 维普 万方数据 等数据库收录! |