摘    要:由于电力变压器的故障原因、故障现象和故障机理间存在着随机性和模糊性等不确定因素,故障特征量和故障征兆间没有明确的一一对应关系,为了用特征量的数值大小来衡量和确定故障发生的原因和严重程度,在深入对变压器油中溶解气体分析的基础上,按照聚类分析的思想,运用模糊C-均值聚类分析原理(Fuzzy C-Means,FCM)和IEC三比值法,将这两种故障类型识别的方法在特征气体诊断分析中进行有效结合,建立了多诊断方法的系统框架。该法可以定量地确定故障在特征气体空间上的聚集效应,从而达到对故障进行自动合理分类的目的。仿真得出该方法正判率为98.1%,较IEC比值法、FCM算法的正判率分别提高了3.6%、4.5%。结果表明该方法具有很高的可行性和有效性。

关 键 词:模糊C-均值聚类算法  油中溶解气体  故障诊断  聚集效应  IEC三比值法  聚类分析
文章编号:1003-6520(2007)08-0066-05
修稿时间:2006-12-28

New Fault Diagnosis Method of Power Transformer by Combination of FCM and IEC Three-ratio Method
YANG Ting-fang,LIU Pei,LI Jing-lu,HU Yi. New Fault Diagnosis Method of Power Transformer by Combination of FCM and IEC Three-ratio Method[J]. High Voltage Engineering, 2007, 33(8): 66-70
Authors:YANG Ting-fang  LIU Pei  LI Jing-lu  HU Yi
Affiliation:1. School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China;2. School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha 410076, China; 3. Wuhan High Voltage Research Institute of SGCC, Wuhan 430074, China
Abstract:Due to lack of interaction between IEC three ratio codes and other methods to diagnose transformer such as neural network,fuzzy expert system,genetic algorithm and artificial intelligence technique,most advantage and characteristics of IEC three ratio codes can not be revealed.According to the ideal of cluster analysis,Fuzzy C-Means(FCM) combined with IEC three-ratio method was adopted based on thorough analysis of dissolved gas in transformer to quantitatively depict the aggregation effect of characteristic gas space,which can categorize faults automatically and reasonably and also enhance the veracity and reliability of diagnosis with conventional IEC three ratio method in power transformer.Simulation results show the high feasibility and effectiveness of this way.Power transformer is one of the most important devices in electric power system.And monitoring the components of dissolved gas-in-oil can discover its operation problem,thereby,avoid availably electric power grid running accidents caused by power transformer fault.To use dissolved gas analysis(DGA) in oil can detect the potential fault of power transformer.As uncertain factors such as fuzziness and random exist among fault causes,fault phenomenon and fault type of power transformer,no correct one to one corresponding relations indwell in fault characteristic quantity and symptom of fault.Thus characteristic quantity cannot measure and identify fault causes and severity.So far one of main methods for transformer fault diagnosis is IEC three ratio codes.Though it has the defect of criterion lacking for transformer failure codes on critical value and other problems,it becomes the most common used method of current preventive test for power transformer.However,due to the problem of seldom interaction between IEC three ratio codes and other methods to diagnose transformer such as neural network,fuzzy expert system,genetic algorithm and artificial intelligence technique,most advantage and characteristics of IEC three ratio codes can not be revealed from these ways.According to the ideal of cluster analysis,Fuzzy C-Means(FCM) combined with IEC three-ratio method is adopted based on thorough analysis of dissolved gas in transformer to quantificational depict aggregation effect of characteristic gas space,which can categorize faults automatically and reasonably and also enhance the veracity and reliability of diagnosis with conventional IEC three ratio method in power transformer.Simulation results show the accurate judgement rate obtained using this new method is 98.1%,which is higher than IEC three ratio codes and FCM methods by 6.3% and 4.5% respectively.Results show the high feasibility and effectiveness of this way.
Keywords:Fuzzy C-means method  dissolved gas-in-oil  fault diagnosis  aggregation effect  IEC three ratio codes  cluster analysis