首页 | 本学科首页   官方微博 | 高级检索  
     


Dynamic simulation of fouling in a circulating fluidized biomass-fired boiler
Authors:Jan Sandberg  Rebei Bel Fdhila  Erik Dahlquist  Anders Avelin
Affiliation:1. Department of Energy Technology, Fluid Dynamics Research Group, Mälardalen University, Box 883, SE – 721 23 Västerås, Sweden;2. ABB Corporate Research, Department of Automation Technology, Forsgränd 7, SE – 721 78 Västerås, Sweden
Abstract:A dynamic model is presented for a biomass-fired circulating fluidized bed boiler. The model is based on energy and mass balances for the components in the boiler and on a combustion model for the fluidized bed. The main purpose of the model is to simulate how deposits affect the boiler efficiency and performance. The model is verified against the municipal circulating fluidized bed boiler in Västerås, Sweden, which produces 157 MW. The distribution of deposits on the surfaces in the boiler is well known from inspections. These observations are used as inputs to the model to simulate their effects on boiler performance.
Keywords:Dynamic model  CFB boiler  Fouling  Superheater tubes  Deposit layer  Biomass-fired boiler
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号