黄瓜中溴离子的离子色谱法测定
引用本文:范志先,王树娟,贾淑敏,肖祥勇.黄瓜中溴离子的离子色谱法测定[J].青岛科技大学学报,2010,31(3):256-258.
作者姓名:范志先  王树娟  贾淑敏  肖祥勇
作者单位:青岛科技大学化工学院,山东,青岛,266042 
摘    要:在优化前处理方法的基础上,研究了以水为提取溶剂,SAX-SPE柱净化,AS 9-HC柱分离,电导检测器测定黄瓜中溴离子含量的离子色谱分析方法。Br-标准溶液浓度0.5~300 mg.L-1,标准曲线方程为Y=-306 756+2 639 978X,r=0.998 4,方法的最低检出浓度为0.2 mg.kg-1。样品(低于方法最低检出浓度)添加1,100 mg.kg-1Br-的平均回收率分别为98.6%,90.6%;相对标准偏差为13.47%,9.67%,准确度和精密度符合要求。测定的青岛5个菜市场黄瓜样品中溴离子浓度均低于方法的最低检出浓度。

关 键 词:离子色谱法  SAX-SPE柱  黄瓜  溴离子

Determination of Bromine Ion Content in Cucumber by Ion Chromatography
Abstract:A method was established for determining bromine ion in cucumber by ion chromatography on the basis of optimizing the pretreatment methods.The anions were extracted with redistilled water and cleaned up with SAX-SPE column.The separation of anions was achieved on an AS 9-HC column,and conductivity detector performed by the detection.The linearity of the calibration curve was good in the rang of 0.5—300 mg·L-1 and the equation was Y=-306 756+2 639 978X,r=0.998 4,LOD is 0.2 mg·kg-1.The mean recoveries at the level of 1 and 100 mg·kg-1Br-were 98.6 %,90.6 %with RSD of 13.47 %,9.67 %,respectively.The accuracy and the precision of the method accorded with the requirements of analysis.The determination results of five cucumber samples were lower than LOD which came from Qingdao food markets.
Keywords:ion chromatography  SAX-SPE column  cucumber  bromine ion
本文献已被 CNKI 维普 万方数据 等数据库收录!