首页 | 本学科首页   官方微博 | 高级检索  
     


Installation of a multiplexed Raman system in a chemical process
Authors:Weyer Lois G  Yee Dupon  Pearson Gary I  Wade John
Affiliation:ATK Elkton LLC, 55 Thiokol Road, Elkton, Maryland 21921, USA.
Abstract:A 785 nm laser dispersive Raman system was installed in a hazardous chemical production plant to monitor two reactors, a still, and a holding tank with measurement directly through sight glasses. Compositional information for several raw materials, intermediates, and products was obtained using partial least squares (PLS) calibrations. Discriminate analysis was used to exclude extremely poor spectra while including usable ones. Derivative/standard normal variate (SNV) treatment was found to be effective for correcting for background fluorescence and for large differences in spectral intensity. Final regression equations incorporated temperature fluctuations, occasional fluorescence, some sunlight effects, large intensity variations, and large compositional changes. Various installation problems were solved via data treatment or mechanical changes. The Raman system provides information for control of the process, resulting in cost savings and improved safety.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号