首页 | 本学科首页   官方微博 | 高级检索  
     


Enhanced removal of humic acid from water by micelle-montmorillonite composites: Comparison to granulated activated carbon
Authors:Adi Radian  Michal Carmeli  Dikla Zadaka-Amir  Shlomo Nir  Eliyahu Wakshal  Yael G. Mishael
Affiliation:1. Graduate School of Integrated Arts and Sciences, Hiroshima University, 1-7-1 Kagamiyama, Higashi-Hiroshima 739-8521, Japan;2. Division of Material Science, Graduate School of Science and Engineering, Saitama University, 255 Shimo-okubo, Sakura-ku, Saitama 338-8570, Japan;3. Graduate School of Design, Kyushu University, 4-9-1 Shiobaru, Minami-ku, Fukuoka 815-8540, Japan;4. Department of Contemporary Social Studies, Faculty of Contemporary Social Studies, Chikushi Jogakuen University, 2-12-1 Ishizaka, Dazaifu, Fukuoka 818-0192, Japan
Abstract:Removal of humic acid (HA) from water by octadecyltrimethyl-ammonium (ODTMA) micelle–montmorillonite (MMT) composites and by granulated activated carbon (GAC) was studied in dispersion and by filtration. FTIR measurements emphasized that the ODTMA micelle–clay-mineral composite differs from the ODTMA monomer-clay-mineral one. HA adsorption by GAC in dispersion was moderately reduced from 100% initially to 75% with an increase in HA concentrations. In contrast, the fractions adsorbed by the composite increased monotonically with HA concentrations from very low adsorption up to 80%. This effect was explained by the presence of a small concentration of ODTMA monomers in dispersion, which adsorbed on the negatively charged HA and partially neutralized it, or caused charge reversal, which in turn inhibited HA adsorption by the positively charged composite. This effect was verified by mobility measurements and was found to be more pronounced at low HA concentrations. This trend of increase in HA removal with an increase in HA concentration (3 and 10 ppm) was also observed in filtration (50% and 85% removal, respectively), when employing columns of the composite mixed with sand (to improve flow). Throughout the experiment the removal of high HA concentration (10 ppm) by the composite filter remained ~ 80% whereas, the removal by the GAC filter decreased from an initial 80% removal to a complete recovery of the HA (no removal) after the passage of 20 L (200 pore volumes). Upon applying sand of higher quality in the columns the removal of low HA concentrations was nearly complete by the composite column while the GAC only slightly contributed to its removal (for a passage of 100 L (1000 pore volumes)).
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号