首页 | 本学科首页   官方微博 | 高级检索  
     


A Gait Phase Measurement System Using Treadmill Motor Current
Authors:Takeshi Ando  Eiichi Ohki  Yasutaka Nakashima  Yutaka Akita  Hiroshi Iijima  Osamu Tanaka
Affiliation:1. Waseda University , 3-4-1 59-309, Ohkubo, Shinjyuku, Tokyo , 169-8555 , Japan;2. Yokohana Rehabilitation Foundation , 1770, Toriyamacyo, Kouhoku, Yokohama , 222-0035 , Japan fantasista@suou.waseda.jp;4. Yokohana Rehabilitation Foundation , 1770, Toriyamacyo, Kouhoku, Yokohama , 222-0035 , Japan
Abstract:The article describes the development of a gait phase time-based split-belt treadmill measurement system. Conventional methods of measuring gait phase, such as the foot switch and force plate, require significant preparation and are costly. In this article, we propose a simple, cheap, and accurate gait phase measurement system that utilizes only the treadmill motor current value. Comparison of this algorithm with conventional methods reveals that the proposed algorithm is as accurate as the foot switch. Moreover, the proposed algorithm can estimate stance phase within a 0.2?s error of the measured value of the force plate in most cases (four out of five healthy subjects). This accuracy is higher than that of the foot switch which is widely used in the clinical field.
Keywords:rehabilitation robot  gait phase  treadmill motor current
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号