江山电厂电除尘器效果差的原因分析及改进
引用本文:宋?,运强. 江山电厂电除尘器效果差的原因分析及改进[J]. 湖北电力, 2001, 25(4): 43-45
作者姓名:宋?  运强
作者单位:荆门热电厂
摘    要:针对华能江山电厂所配电除尘器除尘效果差的问题,从设备先天不足和运行条件的变化方面分析了效果差的原因,提出从根本上解决问题的意见,并就几种振打方式进行了初步的比较和论证。

关 键 词:电厂 电除尘器 检修
文章编号:1006-3986(2001)04-0043-03
修稿时间:2001-05-16

Analysis and Improvement for Low Dusting Efficiency of Electric Precipitators in Jiangshan Power Plant
SONG Yun qiang. Analysis and Improvement for Low Dusting Efficiency of Electric Precipitators in Jiangshan Power Plant[J]. Hubei Electric Power, 2001, 25(4): 43-45
Authors:SONG Yun qiang
Abstract:For the problem of low dusting efficiency of electric precipitators installed in Jiangshan Power Plant of China Energy Co., the reason of this poor efficiency was analyzed on the basis of the e-quipments inherent defects and the changes of the operation condition. The suggestions for completely solving these problems were given out. The preliminary comparison and discussion about several dinds of vibration manners were conducted.
Keywords:technical demonstration  improvement suggestion  reson analysis  electric precipitator