摘    要:建立了离子色谱法测定焦化废水中多种阴离子的方法.比较了液液萃取、真空抽滤、固相萃取3种处理方法.用电导检测器同时测定了焦化废水中的F-、Cl-、N02-、N03-、PO43--含量.离子色谱法的回收率为69%~110%,相对标准偏差为0.13%~3.6%.

关 键 词:离子色谱  焦化废水  阴离子

Determination of anions in coking waste water by ionic chromatography
Cheng Yaping.Determination of anions in coking waste water by ionic chromatography[J].Fuel & Chemical Processes,2012,43(2):37-39.
Authors:Cheng Yaping
Affiliation:Cheng Yaping (Meishan Branch of Shanghai Baosteel Chemical Co., Ltd., Nanjing 210039, China)
Abstract:The method for determination of many kinds of anions in coking waste water by ionic chromatography is established. The 3 kinds of treating methods of liquid-liquid extraction, vacuum pumping and filtering and solid phase extraction are compared. The contents of F-,Cl-,NO2-,NO3-,PO43- in coking waste water are determined by electric conductivity detector simultaneously. The recovery rates of ionic chromatography range from 69% to 110% and relative standard deviations are in the range from 0.13% to 3.6%.