首页 | 本学科首页   官方微博 | 高级检索  
     

核电站蒸汽发生器用Incoloy800H传热管抗晶间腐蚀性能研究
引用本文:韩建成,李巨峰,吴志军,石长仁,王毅,于光强.核电站蒸汽发生器用Incoloy800H传热管抗晶间腐蚀性能研究[J].热力发电,2012,41(1):50-52,64.
作者姓名:韩建成  李巨峰  吴志军  石长仁  王毅  于光强
作者单位:华能山东石岛湾核电有限公司,山东荣成,264312
摘    要:对核电站蒸汽发生器用Incoloy800H传热管在不同敏化条件下进行晶间腐蚀试验,结果表明,未经敏化处理而直接进行晶间腐蚀试验的试样未见明显宏观裂纹,而经敏化处理的试样发生了不同程度的宏观裂纹,且敏化时间越长,裂纹倾向越严重。因此,为提高Incoloy800H传热管的抗晶间腐蚀能力,应降低C含量,提高Ti含量,同时严格控制介质的环境,以避免传热管晶间腐蚀裂纹的发生。

关 键 词:核电站  蒸汽发生器  传热管  Incoloy800H  晶间腐蚀

STUDY ON THE INTERCRYSTALLINE CORROSION RESISTANT ABILITY OF Incoloy800H HEAT TRANSFER TUBES
HAN Jiancheng , LI Jufeng , WU Zhijun , SHI Changren , WANG Yi , YU Guangqiang.STUDY ON THE INTERCRYSTALLINE CORROSION RESISTANT ABILITY OF Incoloy800H HEAT TRANSFER TUBES[J].Thermal Power Generation,2012,41(1):50-52,64.
Authors:HAN Jiancheng  LI Jufeng  WU Zhijun  SHI Changren  WANG Yi  YU Guangqiang
Affiliation:Huaneng Shandong Shidaowan Nuclear Power Co Ltd,Rongcheng 264312,Shandong Province,PRC
Abstract:The result of test on intercrystalline corrosion of Incoloy800H heat transfer tubes used for steam generator in nulcear power plant under different conditions of sensitization has been analysed.Results show that the remarkable intercrystalline cracks have not appeared on sample,which were directly being tested and hadn’t carried out any sensitization treatment,however,macroscopic cracks have occurred in different degrees on samples after sensitization treatment,and the longer the sensitization time was,the more severe tendeny of cracking had.In order to enhance the intercrystalline corrosion resistant ability of Incoloy800H heat transfer tubes,the C content has to be reduced,and the Ti content has to be increased,at the same time,the environment of mediums should be strictly controlled,so as to avoid the interstalline cracks occurred on the heat transfer tubes.
Keywords:nuclear power plant  steam generator  heat transfer tube  Incoloy800H  intercrystalline corrosion