Oscillator analysis with respect to higher harmonics |
| |
Authors: | J. Kadlec J. Macháč |
| |
Affiliation: | (1) Faculty of Electrical Engineering, Czech Technical University, Techniká 2, Prague 6, Czechoslovakia |
| |
Abstract: | Contents The modified harmonic balance method has been worked out to describe the behaviour of oscillators generating output signal not on the first harmonic, as it is usual, but on the higher one. The main assumptions are: All higher harmonics are considered small compared to the first one and there is only one dominant resistive nonlinearity limiting amplitude of oscillations. The approximate solution of a microwave oscillator with Gunn diode is presented as an example. The results are in accordance with experimentally observed phenomena in the oscillator such as discontinuities and power drops in its characterstics.
Oszillator-Analyse mit höheren Harmonischen Übersicht Die Methode der modifizierten Harmonischen-Bilanzierung wurde weiterentwickelt, um das Verhalten von Oszillatoren zu beschreiben, die nicht wie üblich Signalleistung auf der Fundamentalen abgeben, sondern auf höheren Harmonischen. Dabei wird als wesentlich angenommen, daß die Amplituden der höheren Harmonischen klein sind, verglichen mit der ersten, und daß nur eine resitive Nichtlinearität dominierend die Schwingamplitude begrenzt.Als Beispiel wird die Näherungslösung eines Mikrowellenoszillators mit Gunn-Element vorgestellt. Die Lösungsergebnisse stimmen mit experimentelll beobachteten Erscheinungen im Oszillatorbetriebsverhalten überein, wie Kurvensprüngen und Leistungseinbrüchen. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|