Abstract:Dynamic mechanical response parameters (stiffness, damping and effective mass), physiological properties (strength and swelling) and symptoms of the upper limb were measured before power tool operation, immediately following and 24?h after power tool operation. Tool factors, including peak torque (3 Nm and 9 Nm) and torque build-up time (50?ms and 250?ms), were controlled in a full factorial design. Twenty-nine inexperienced power hand tool users were randomly assigned to one of four conditions and operated a pistol grip nutrunner four times per min for 1?h in the laboratory. Isometric strength decreased immediately following tool use (15%) (p?<?0.01) and 24?h later (9%) (p?<?0.05). Mechanical parameters of stiffness (p?<?0.05) and effective mass (p?<?0.05) were affected by build-up time. An average decrease in stiffness (43%) and effective mass (57%) of the upper limb was observed immediately following pistol grip nutrunner operation for the long (250?ms) build-up time. A previously developed biomechanical model was used to estimate handle force and displacement associated with the tool factors in the experiment. The conditions associated with the greatest predicted handle force and displacement had the greatest decrease in mechanical stiffness and effective mass, and the greatest increase in localized discomfort.