首页 | 本学科首页   官方微博 | 高级检索  
     


Carcinoembryonic antigen admittance biosensor based on Au and ZnO nanoparticles using FFT admittance voltammetry
Authors:Norouzi Parviz  Gupta Vinod Kumar  Faridbod Farnoush  Pirali-Hamedani Morteza  Larijani Bagher  Ganjali Mohammad Reza
Affiliation:Center of Excellence in Electrochemistry, University of Tehran, Tehran, Iran. norouzi@khayam.ut.ac.ir
Abstract:In this work, a highly sensitive carcinoembryonic antigen fast Fourier transform admittance biosensor is introduced. The proposed biosensor is based on bilayer films of ZnO/Au nanoparticles as an immobilization matrix. These layers are prepared by self-assembly and deposition method on a gold electrode surface, respectively. Carcinoembryonic antibody (anti-CEA) was immobilized on gold nanoparticles and positively charged horseradish peroxidase (HRP) was used to block sites against nonspecific binding. The admittance biosensor was developed based on fast Fourier transform continuous square wave voltammetry, which produces a sensitive, fast (less than 20 s) and reliable response for determination of carcinoembryonic antigen. The technique was applied as a detector in a flow injection system. The admittances reduction current of the biosensor decreases linearly in two concentrations ranges of CEA from 0.1 to 70 ng/mL and from 70 to 200 ng/mL with a detection limit of 0.01 ng/mL in presence of 0.5 mM H(2)O(2) as an eluent solution.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号