摘    要:提出的电流互感器误差低压外推测试法,是将现场电流互感器当作误差相同的电压互感器进行测试,先在200%~1000%额定电压(电流)下测互感器的误差和导纳等参数,再通过在1%~120%额定电压(电流)下测导纳,进而由公式推算出电流互感器的误差。测试结果表明与传统方法相符,故这种新方法的推广、应用将对现场电流互感器的检定产生深远的影响。

关 键 词:电流互感器  电压互感器  误差  外推法
文章编号:1001-1390(2004)12-0028-03
修稿时间:2004-09-10

Error Test of Current Transformers with Low-voltage Deduced Method
ZHAO Xiu-min,ZHAO Yi-tao. Error Test of Current Transformers with Low-voltage Deduced Method[J]. Electrical Measurement & Instrumentation, 2004, 41(12): 28-30
Authors:ZHAO Xiu-min  ZHAO Yi-tao
Abstract:It is described in this paper, the error of current transformers could be tested by using deduced method, a current transformer could be tested as a v oltage transformer with the same error. At first, error and admittance could be tested at 200% to 1000% rated voltage(current), then error could be obtained aft er the calculation and the admittance tested at 1% to 120% rated voltage(current ). The generalization and application of this new method would bring a great eff ect to the calibration of locale current transformers.