首页 | 本学科首页   官方微博 | 高级检索  
     

带翅片的小型平板CPL蒸发器相变传热的数值模拟
引用本文:万忠民,刘伟,盖东兴,刘志春.带翅片的小型平板CPL蒸发器相变传热的数值模拟[J].化工学报,2007,58(12):2994-3000.
作者姓名:万忠民  刘伟  盖东兴  刘志春
作者单位:华中科技大学能源与动力工程学院,湖北 武汉 430074
基金项目:国家重点基础研究发展规划(973计划)
摘    要:提出一种小型平板毛细抽吸两相流体回路(CPL)系统来实现电子元器件散热,分析了其工作原理及特点。针对小型平板式CPL蒸发器的结构特点,分析了蒸发器侧壁导热所引起的侧壁效应对CPL传热能力的影响,提出小型平板CPL存在侧壁效应传热极限。为了提高系统的传热能力,蒸发器下壁增设了散热翅片。建立了小型平板CPL蒸发器毛细多孔芯的二维气液两相分层饱和多孔介质模型,金属壁面及工质气、液空间区域耦合的数学模型,并用SIMPLE算法对模型进行求解。数值研究表明,蒸发器受热面的温度水平较低,均温性较好。蒸发器采用翅片可以增加多孔芯内的温度梯度,使芯内温度分布更加合理;可以降低加热表面以及下壁温度,提高了侧壁效应传热极限,增强了系统的传热能力。

关 键 词:毛细抽吸两相流体回路  小型平板式  蒸发器  侧壁效应传热极限  翅片  电子器件散热  
收稿时间:2007-2-6
修稿时间:2007-6-21  

Numerical simulation of heat transfer with phase change in small-scale flat capillary pumped loop finned evaporator
WAN Zhongmin,LIU Wei,GAI Dongxing,LIU Zhichun.Numerical simulation of heat transfer with phase change in small-scale flat capillary pumped loop finned evaporator[J].Journal of Chemical Industry and Engineering(China),2007,58(12):2994-3000.
Authors:WAN Zhongmin  LIU Wei  GAI Dongxing  LIU Zhichun
Abstract:The small-scale flat capillary pumped loop(CPL)for the cooling of electronic apparatus was presented,and its operation principle and characteristics were analyzed.Based on the structure characteristics of small-scale flat CPL evaporator,the effect of metal side wall conduction of evaporator on the CPL work limit was analyzed,and the heat transfer limit of side wall effect was introduced.In order to improve the heat transfer capacity of CPL,fins were added on the bottom of evaporator.The flow and heat transfer in the porous structure were modeled by using two-phase layered saturated porous model,and the conduction models of metal wall and fluid region were established.The entire evaporator was solved with the SIMPLE algorithm as a conjugate problem.The numerical results showed that the heated surface temperatures of the evaporator were low,and the temperature difference along the heated surface was small.The temperature gradients in the wick structure of evaporator with fins increased,and the temperature distribution in the wick structure was reasonable.The temperatures of heated surface and bottom metal wall of finned evaporator decreased,and the heat transfer capacity was improved remarkably.
Keywords:capillary pumped loop  small-scale flat type  evaporator  heat transfer limit of side wall effect  fins  heat dissipation of electronic apparatus
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《化工学报》浏览原始摘要信息
点击此处可从《化工学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号