首页 | 本学科首页   官方微博 | 高级检索  
     

2万吨/年事故氯气处理装置尾气风机的选型计算
引用本文:宁绍宇,李 娟. 2万吨/年事故氯气处理装置尾气风机的选型计算[J]. 辽宁化工, 2014, 0(3): 310-311
作者姓名:宁绍宇  李 娟
作者单位:[1]化工部长沙设计研究院沈阳分院,辽宁沈阳110026 [2]辽宁省科学技术馆,辽宁沈阳110167
摘    要:介绍了2万t/a离子膜烧碱(折100%NaOH)事故氯气处理装置尾气风机总风量的计算方法。计算出事故氯气处理装置尾气风机总风量为1 025 Nm3/h。

关 键 词:事故氯气处理  饱和蒸汽压  风机  总风量

Selection Calculation of Exhaust Fan for Incident Chlorine Treatment Device in 20 kt/a Ionic Membrane Caustic Soda Unit
NING Shao-yu,LI Juan. Selection Calculation of Exhaust Fan for Incident Chlorine Treatment Device in 20 kt/a Ionic Membrane Caustic Soda Unit[J]. Liaoning Chemical Industry, 2014, 0(3): 310-311
Authors:NING Shao-yu  LI Juan
Affiliation:2 ( 1. Shenyang Branch of the Ministry of Chemical Industry, Changsha Design and Research Institute, Liaoning Shenyang 110026, China; 2. Science and Technology Museum of Liaoning, Liaoning Shenyang 110167, China)
Abstract:The calculation method on the total air volume of exhaust fan in 20 kt/a ionic membrane caustic soda unit was described. The total air volume of exhaust fan in 20 kt/a ionic membrane caustic soda unit was determined.
Keywords:accident chlorine treatment  saturated vapor pressure  exhaust fan  total air volume