首页 | 本学科首页   官方微博 | 高级检索  
     

钢筋网和钢筋混凝土屏蔽效能研究
引用本文:高长征,李琳,崔翔,赵志斌,谷雪松.钢筋网和钢筋混凝土屏蔽效能研究[J].电工技术学报,2005,20(6):35-40.
作者姓名:高长征  李琳  崔翔  赵志斌  谷雪松
作者单位:华北电力大学电气工程学院,保定,071003;华北电力大学电气工程学院,保定,071003;华北电力大学电气工程学院,保定,071003;华北电力大学电气工程学院,保定,071003;华北电力大学电气工程学院,保定,071003
基金项目:高等学校博士学科点专项科研项目
摘    要:利用矩量法和时域有限差分法计算分析了由钢筋网和钢筋混凝土构成的实际屏蔽体的屏蔽效能,总结了钢筋直径、钢筋网格尺寸和混凝土特性等因素对屏蔽效能影响的基本规律.通过对实际钢筋网屏蔽体屏蔽效能的测量进一步验证了所用数值计算方法对于计算此类问题的有 效性.分析了无限大金属网屏蔽效能计算公式在计算钢筋网屏蔽体屏蔽效能的参考价值和局限性.探讨了使用钢筋混凝土作为变电站保护小间屏蔽材料的可行性,为实际工程设计提供了依据.

关 键 词:保护小间  屏蔽效能  钢筋混凝土  矩量法  时域有限差分法
修稿时间:2004年3月17日

Study of Shielding Effectiveness of Reinforcing Bar Mesh and Reinforced-Concrete
Gao Changzheng,Li Lin,Cui Xiang,Zhao Zhibin,GU Xuesong.Study of Shielding Effectiveness of Reinforcing Bar Mesh and Reinforced-Concrete[J].Transactions of China Electrotechnical Society,2005,20(6):35-40.
Authors:Gao Changzheng  Li Lin  Cui Xiang  Zhao Zhibin  GU Xuesong
Affiliation:North China Electric Power University Baoding 071003 China
Abstract:For EMC compliance, the study on the shielding effectiveness (SE) of the reinforced-concrete is valuable. Because the SE of reinforced-concrete is mainly depended on the reinforcing wire in it, and it is convenient to calculate a complex structure with metal wire structure by moment method (MoM). The SE of actual shielding built with wire-mesh reinforcement is studied by NEC software based on MoM. At the same time, the SE of a model built with wire-mesh reinforcement is tested and the results of experiment also prove that the numerical method used in the paper is validity. Furthermore, the reference value and limitation in the computation of the actual shielding by the analytical formulas, which are used in the calculation of SE of infinite metal mesh are analyzed. In order to analyses the SE of the actual shielding built with wire-mesh reinforcement and reinforced-concrete for transient electromagnetic field, the finite difference time domain method (FDTD) is also used. Finally, the factors that can affect the SE of the reinforced-concrete such as the size of the grid, radius of the reinforcing wire and others are summarized. In order to reduce the cost of engineering, the feasibility of using reinforced-concrete as shielding material for the relay-cell in substation is studied. Some valuable conclusions are reached.
Keywords:Relay-cell  shielding effectiveness  reinforced-concrete  moment method  FDTD method
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号