首页 | 本学科首页   官方微博 | 高级检索  
     

基于声发射信号频率位移的催化剂积炭量检测
引用本文:唐玥祺,王靖岱,廖祖维,阳永荣,谢在库. 基于声发射信号频率位移的催化剂积炭量检测[J]. 石油学报(石油加工), 2010, 26(6): 917-917. DOI: 10.3969/j/issn.1001-8719.2010.06.014
作者姓名:唐玥祺  王靖岱  廖祖维  阳永荣  谢在库
作者单位:1. 浙江大学,化学工程联合国家重点实验室,化学工程与生物工程学系,浙江,杭州,310027
2. 中国石化,上海石油化工研究院,上海,201208
基金项目:国家自然科学基金项目,中央高校基本科研业务费专项资金
摘    要: 基于气-固流化床内催化剂颗粒运动碰撞反应器壁面产生声发射信号的机理,借助多次扫描累加及平滑消噪等处理手段,结合功率谱分析,获得了代表催化剂颗粒运动的特征信号频率。同时,基于特征信号频率随结焦催化剂的不同积炭量的规律性变化,建立了声发射测量结焦催化剂积炭量的预测模型,即C(i)=a△f(i)+b,其中△f(i)为反应器i高度声发射信号功率谱特征峰的频率位移,a和b为拟合参数。在不同表观气速下和不同探头高度处,该模型均能预测催化剂积炭量,且预测值与实际值的平均相对误差(AARD)小于8.12%。由此,获得了一种快捷灵敏、安全环保的非侵入式结焦催化剂积炭量检测技术,能够实现流化床内结焦催化剂积炭量的实时在线监控。

关 键 词:声发射检测  积炭量  功率谱分析  消噪
收稿时间:2009-08-17
修稿时间:2009-11-30

MEASUREMENT OF THE AMOUNT OF COKE DEPOSIT ON CATALYST BASED ON ACOUSTIC EMISSION FREQUENCY SHIFT
TANG Yueqi,WANG Jingdai,LIAO Zuwei,YANG Yongrong,XIE Zaiku. MEASUREMENT OF THE AMOUNT OF COKE DEPOSIT ON CATALYST BASED ON ACOUSTIC EMISSION FREQUENCY SHIFT[J]. Acta Petrolei Sinica (Petroleum Processing Section), 2010, 26(6): 917-917. DOI: 10.3969/j/issn.1001-8719.2010.06.014
Authors:TANG Yueqi  WANG Jingdai  LIAO Zuwei  YANG Yongrong  XIE Zaiku
Affiliation:1. State Key Laboratory of Chemical Engineering, Department of Chemical and Biochemical Engineering, Zhejiang University, Hangzhou 310027, China;2. Shanghai Research Institute of Petrochemcal Technology, SINOPEC, Shanghai 201208, China
Abstract:The characteristic frequency of acoustic emission (AE) in a fluidized bed with respect to the behavior of catalyst particles movement was obtained by analyzing the power spectrum after denoising based on the mechanism of interaction between particles and the internal wall of the fluidized bed. A model to predict the amount of coke deposit on catalyst was established to describe the correlation between the characteristic frequency of AE signals from the particles-wall collisions and coke deposit. The corresponding relationship could be expressed as C(i)=a f(i)+b, in which f(i) was the frequency shift of characteristic peak at height i of the fluidized bed, and a and b were the fitting parameters. Experimental results in a cold mode fluidized bed showed that this model was useful to measure the amount of coke deposit on catalyst at different superficial gas velocity and different sensor height. The average absolute relative deviation (AARD) was below 8.12% when the predicted amount of coke deposit was compared with the true one. Therefore, it could be concluded that the model could meet the requirements of online measurement of the amount of coke deposit on catalyst in fluidized beds.
Keywords:acoustic emission frequency shift  the amount of coke deposit  power spectrum density analysis  denoise
本文献已被 万方数据 等数据库收录!
点击此处可从《石油学报(石油加工)》浏览原始摘要信息
点击此处可从《石油学报(石油加工)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏