一起粗氩塔堵塞引起上塔液悬故障的调整、分析与处理
引用本文:柴敬尧.一起粗氩塔堵塞引起上塔液悬故障的调整、分析与处理[J].冶金动力,2014(9):32-34.
作者姓名:柴敬尧
作者单位:鞍山宝得钢铁有限公司制氧厂;
摘    要:6500 m3/h空分设备中的粗氩塔在运行过程中发生了故障,导致氩中含氧急剧上升。经故障查找排除了填料冰堵原因,认为是粗氩塔冷凝器发生氩固化所致,在工艺操作控制上采取了相应的防范措施,避免了故障再次发生,保证了正常生产。

关 键 词:粗氩塔  堵塞  故障  氩固化

Adjustment,Analysis and Treatment of an Upper Column Liquid Suspending Accident Caused by Blocking in Crude Argon Column
CHAI Jingyao.Adjustment,Analysis and Treatment of an Upper Column Liquid Suspending Accident Caused by Blocking in Crude Argon Column[J].Metallurgical Power,2014(9):32-34.
Authors:CHAI Jingyao
Affiliation:CHAI Jingyao (Oxygen Making Plant of Anshan Debao Iron and Steel Co. Ltd., Anshan, Liaoning 114000, China)
Abstract:The crude argon column of the 6 500 m3/h air separator failed during opera-tion, leading to sharp rise of oxygen content in argon. Through troubleshooting icing blocking of fillings was ruled out while argon solidification in the condenser of the crude argon column was pinpointed to be the cause. Countermeasures of technological operation control were taken, which prevented such accident happening again and ensured normal production.
Keywords:crude argon column  blocking  failure  argon solidification