Abstract: | Conclusions 1. | The complexity of the theoretical solution of the problem of the discharge capacity of a broad-crested weir working under three-dimensional conditions, dictates the need for considerable experimental investigations. | 2. | On the basis of the experimental results new calculation graphs and dependences were obtained and are recommended for use when designing intake works patterned after a broad-crested weir and when estimating their capacity. The accuracy of the calculated parameters in 3–5%. | Translated from Gidrotekhnicheskoe Stroitel'stvo, No. 1, pp. 45–51, January, 1999. |