Abstract:The article presents a procedure to qualify the Trio_U code for the prediction of the boron concentration at the core inlet of a French 900 MWe pressurized water reactor under accidental conditions (inherent dilution problem).1 The objective of this procedure is to ensure that the validation calculations are performed with the same modelling hypotheses as the full scale reactor analysis, for which usually no experimental data are available. A density driven ROCOM experiment as well as an UPTF Tram-C3 experiment have been used for the qualification of the Trio_U code. Both experiments present similar thermal hydraulic conditions as the reactor case. The predicted boron concentration at the core inlet of the reactor shows that the potential return to criticality might not be excluded in the case of a small break LOCA. Further neutronic calculations are necessary to confirm this result.