摘    要:叙述了山西兴能电厂二期600 MW超临界直流锅炉的运行调整方法,指出,锅炉汽温变化是运行调整的主要因素,提出了针对影响燃烧稳定性的调整措施。

关 键 词:超临界直流锅炉  汽温  控制  燃烧  调整

Running Adjustment Experience of 600 MW Supercritical Boiler in the Second Phase of Synergy Power Plant
GUO Wei-long. Running Adjustment Experience of 600 MW Supercritical Boiler in the Second Phase of Synergy Power Plant[J]. Shanxi Energy and Conservation, 2011, 0(5): 75-76
Authors:GUO Wei-long
Affiliation:GUO Wei-long(Shanxi Synergy Power Generation Co.,Ltd.,Gujiao 030206,Shanxi,China)
Abstract:Introduced running adjustment method of 600 MW supercritical boiler in the second phase of Gujiao Power Plant.According to the main factors of the steam temperature changes of boiler,thereafter this paper gives an adjustment analysis,and put forward combustion adjustment measures of main factors that affect combustion stability,which has important reference value for boiler adjustment of the same type.
Keywords:supercritical monotube boiler  steam temperature  control  combustion  adjustment  