过冷器污氮通道堵塞的排除
引用本文:郭孝武,李金枝,李文功. 过冷器污氮通道堵塞的排除[J]. 深冷技术, 2014, 0(3): 66-69
作者姓名:郭孝武  李金枝  李文功
作者单位:河南金利金铅有限公司制氧厂,454650
摘    要:由于过冷器污氮通道被珠光砂堵塞,12000 m3/h空分设备的氧气产量不能达到设计值,由于后续生产系统需要无法停车检修,只能采取临时措施保持氧气产量的正常供应,最终通过扒砂并更换过冷器使故障得到彻底排除。介绍故障发生时空分设备技术参数的变化情况和原因分析过程。

关 键 词:空分设备  过冷器  珠光砂  堵塞  氧气产量

Elimination of blocking of waste nitrogen passage of sub-cooler
Guo Xiaowu,Li Jinzhi,Li Wengong. Elimination of blocking of waste nitrogen passage of sub-cooler[J]. Cryogenic Technology, 2014, 0(3): 66-69
Authors:Guo Xiaowu  Li Jinzhi  Li Wengong
Affiliation:(Oxygen Generation Factory, Henan Gold Rakem Lead Co. , Ltd. , Hulin Industry Cluster Area, Jiyuan 454650, Henan, P. R. China)
Abstract:Since the waste nitrogen passage of sub-cooler is blocked by pearlite, the gaseous oxygen output of12000 m^3/h air separation plant fails to reach the designed value. Shutdown and repair is impossible due todemands of the following production system, it has no way but to take temporary measures to ensure normal supply of gaseous oxygen output, and finally the trouble is thoroughly eliminated through removal of the pearlite andreplacement of the sub-cooler. Here, the particulars of change of technical parameters at occurrence of the trouble, and the process of cause analysis are described.
Keywords:Air separation plant  Sub-cooler  Pearlite  Blocking  Gaseous oxygen output