摘    要:氢冷发电机组氢气污染问题严重影响着机组安全运行,从发电机组密封油系统的类型角度,通过对双流环、单流环密封油系统进行对比分析,提出影响氢气纯度下降的主要原因是氢侧密封油空气含量偏高,就如何解决问题提出了3套治理方案。

关 键 词:氢气污染  氢气纯度  双流环密封油系统  单流环密封油系统
文章编号:1008-0198(2004)06-0004-03
修稿时间:2004-02-09

Analysis and Treatment of Hydrogen Pollution in 300MW Hydrogen-Cooling Turbo-Generators
CHENG Gui-b ing. Analysis and Treatment of Hydrogen Pollution in 300MW Hydrogen-Cooling Turbo-Generators[J]. Hunan Electric Power, 2004, 24(6): 4-6
Authors:CHENG Gui-b ing
Abstract:Hydrogen Pollution in 300MW hydrogen-cool in g turbo-generators threatens the unit security operation. By comparison double -flow seal oil with single-flow seal oil, it is pointed out that the main reas on leading hydrogen purity dropping is that the content of air in hydrogen-side seal oil is on the high side. Three methods to treat the problem are provided.