老式高压隔爆配电装置加装综合保护及真空改造
引用本文:李晓刚. 老式高压隔爆配电装置加装综合保护及真空改造[J]. 煤矿机械, 2007, 28(5): 135-136
作者姓名:李晓刚
作者单位:开滦集团有限责任公司,设备管理中心,河北,唐山,063018
摘    要:老式高压隔爆配电装置由于采用多油断路器及其他“先天不足”,与国家现行规程和标准有抵触,已不能适应井下安全供电的要求。采用现代电子保护和真空技术对其进行技术改造,可使上述问题迎刃而解。

关 键 词:老式高压隔爆配电装置  电子综合保护  真空断路器
文章编号:1003-0794(2007)05-0135-02
修稿时间:2006-12-25

Old-fashion High-pressure Explode-isolating Device Adding Synthetic Protection and Vacuum Innovation Technology
LI Xiao-gang. Old-fashion High-pressure Explode-isolating Device Adding Synthetic Protection and Vacuum Innovation Technology[J]. Coal Mine Machinery, 2007, 28(5): 135-136
Authors:LI Xiao-gang
Affiliation:Equipment Management Center of Kailuan Group Co., Ltd., Tangshan 063018, China
Abstract:Due to the over- leaking stopper and its mal - function naturally old - fashion high - pressure explode - isolating device dose not comply with the update national stipulation and standard, and can not satisfy the power- supply safely underneath the coal mine. However, applying modem protection electronically and vacuum technology can solve the above- mentioned problem easily.
Keywords:old - fashion high - pressure explode - isolating device   synthetic protection electronically   vacuum stopper