首页 | 本学科首页   官方微博 | 高级检索  
     

ZDQ-65型水电解装置氢分离洗涤塔爆炸及处理
引用本文:田明勇. ZDQ-65型水电解装置氢分离洗涤塔爆炸及处理[J]. 深冷技术, 2002, 0(4): 49-51
作者姓名:田明勇
作者单位:武汉钢铁集团氧气公司,武汉市青山区厂前,430083
摘    要:分析了武钢氧气公司ZDQ - 6 5型中压水电解装置的氢分离洗涤塔 ,由于违章操作致使电解液循环中断 ,氢氧气体混合产生剧烈的化学爆炸伤人事故的经过、现场调查事故原因分析、事故处理和事故教训。

关 键 词:中压水电解装置  电解液循环中断  氢分离洗涤塔  爆炸  原因分析  处理
文章编号:1009-9425(2002)04-0045-03

Explosion of a hydrogen separation scrubber in model ZDQ-65 water electrolysis system and solutions
Tian Ming-yong. Explosion of a hydrogen separation scrubber in model ZDQ-65 water electrolysis system and solutions[J]. Cryogenic Technology, 2002, 0(4): 49-51
Authors:Tian Ming-yong
Abstract:The paper describes the explosion accident of a hydrogen separation scrubber in model ZDQ-65 water electrolysis system which injured an operator.The severe chemical explosion produced by the mixing of hydrogen and oxygen was caused by the interruption of electrolyte circulation.It has proved on the basis of the site investigation that the accident resulted from irregular operation.In conclusion solutions and lessons taken are given,separately.
Keywords:Medium pressure water electrolysis system  Interruption of electrolyte circulation  Hydrogen separation scrubber  Explosion  Cause analysis  Solution