摘    要:采用硫酸浸出-萃取-反萃工艺流程回收电镀污泥中的铜。运用MATLAB拟合了1 mol/L硫酸体系中铜的浸出动力学模型,表明该浸出过程为扩散和表面反应共同控制。在硫酸浓度1 mol/L、液固比15∶1条件下浸出10 min,铜浸出率达到90%。采用萃取-反萃取的方式回收浸出液中的Cu2+,以Mextral® 984H为萃取剂、Mextral® DT100为稀释剂,在溶液pH=2、萃取时间30 min、O/L相比1∶1、萃取剂浓度10%条件下萃取,铜萃取率可达99%;O/L相比1∶1、反萃取时间30 min,用25%的硫酸溶液进行反萃取,铜反萃取率可达95%。此工艺流程铜总回收率可达85%,实现了铜的高效回收。

关 键 词:电镀污泥    浸出动力学  萃取  反萃取
收稿时间:2019-01-29

Leaching and Solvent Extraction of Copper from Electroplating Sludge
YI Long-sheng,ZHAO Li-hua,XU Yuan-hong,LI Xiao-man.Leaching and Solvent Extraction of Copper from Electroplating Sludge[J].Mining and Metallurgical Engineering,2019,39(4):115-118.
Authors:YI Long-sheng  ZHAO Li-hua  XU Yuan-hong  LI Xiao-man
Affiliation:School of Minerals Processing and Bioengineering, Central South University, Changsha 410083, Hunan, China
Abstract:Copper in electroplating sludge was recovered by adopting a process consisting of sulfuric acid leaching, extraction and stripping in an experiment. The leaching kinetic model data of copper in 1 mol/L H2SO4 system was fitted using MATLAB, indicating that the leaching process was controlled by both diffusion and surface reaction. The copper leaching rate reached 90% from the test under the conditions including the liquid-solid ratio of 15∶1, H2SO4 concentration of 1 mol/L and leaching time of 10 min. Then, Cu2+ in leaching solution was extracted by a process of extractive-reverse extraction under the following conditions: with Mextral® 984H as an extractant, Mextral® DT100 as a diluent, solution pH of 2, the extraction time of 30 min, O/L ratio of 1∶1 and the extractant concentration of 10%, resulting in the extraction rate of 99%; then with 25% sulfuric acid solution as a stripping agent, with O/L ratio of 1∶1 and the reverse extraction time of 30 min, the reverse extraction rate of copper reached 95%. The total copper recovery rate reached 85%, indicating copper in the electroplating sludge was efficiently recovered using this process technique.
Keywords:electroplating sludge  copper  leaching kinetics  extraction  reverse extraction  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《矿冶工程》浏览原始摘要信息
点击此处可从《矿冶工程》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号