斜针翅管强化传热管的数值模拟
引用本文:张延静,江楠.斜针翅管强化传热管的数值模拟[J].石油化工,2009,38(9):975.
作者姓名:张延静  江楠
作者单位:华南理工大学,化工机械与安全工程研究所,广东,广州,510640
摘    要:采用Fluent软件,以水和柴油为换热对象,利用三维模型对柴油在3种不同规格的直针翅管、30°和45°的斜针翅管套管换热器壳程层流流动时的温度场、压降及传热性能进行了模拟;并将斜针翅管与光滑管和直针翅管的结果进行比较。模拟结果表明,壳程为柴油时,针翅管的压降为光滑管的1~3倍,总传热系数约是光滑管的1.7~2.7倍;与直针翅管相比,斜针翅管的总传热系数提高约20%;斜针翅能使传热膜的系数增大,压降降低。

关 键 词:斜针翅管  换热器  数值模拟  强化传热

Numerical Simulation of Enhanced Heat Transfer Tube with Inclined-Pin Fin Tube
Zhang Yanjing,Jiang Nan.Numerical Simulation of Enhanced Heat Transfer Tube with Inclined-Pin Fin Tube[J].Petrochemical Technology,2009,38(9):975.
Authors:Zhang Yanjing  Jiang Nan
Abstract:Numerical simulations was conducted by using three-dimensional model of Fluent software for the case that hot water was flowing in tube side of the heat exchanger and diesel oil as heat-transfer medium was flowing in shell side.Temperature field and heat transfer performances in shell side of a single-tube heat exchanger with three different kinds of fins and with different specifications were simulated.They were straight-pin fin tube,inclination angle of 30° and 45°- inclined-pin fin tubes.Pressure drop with pin-finned tubes were about 1-3 times greater than that with plain tube at same flow conditions.Heat transfer enhancements of pin-finned tube heat exchangers were about 1.7-2.7 times greater than those of plain tube heat exchangers.Compared with straight-pin fin tube,the inclined-pin fin tubes can improve over-all heat transfer coefficient by 20% at most.At the same time it is proved that inclined-pin fin tubes can further enhance film coefficient of heat transfer and lower the pressure drop as compared with the straight-pin fin tube.
Keywords:inclined-pin fin tube  heat exchanger  numerical simulation  enhanced heat transfer