首页 | 本学科首页   官方微博 | 高级检索  
     

两种管外传热型式对振荡管性能的影响
引用本文:李学来,郭荣伟,方曜奇,俞鸿儒. 两种管外传热型式对振荡管性能的影响[J]. 化工学报, 2000, 51(1): 12-16
作者姓名:李学来  郭荣伟  方曜奇  俞鸿儒
作者单位:南京航空航天大学动力系!南京210016,南京航空航天大学动力系!南京210016,大连理工大学化工学院!大连116012,中国科学院力学研究所!北京100080
基金项目:中国科学院资助项目,中国博士后科学基金,59276249,,,
摘    要:对管外换热状况对振荡管性能的影响进行了实验研究及理论分析 .实验中采用自然对流及强制对流 (轴向水冷却 )两种典型的管外换热型式 .结果表明 :改善振荡管外的传热状况 ,可使振荡管的冷效应显著增强 ,在膨胀比ε=2 0~ 6 0的范围内可使制冷效率提高 4 6%~ 5 4% ,同时可使最佳射流激励频率 fopt降低且膨胀比对fopt值不再有明显影响 对导致上述结果的内在机制进行了探讨

关 键 词:传热 振荡流 激波 气体膨胀

OF HEAT TRANSFER CONDITIONS ON PERFORMANCE OF OSCILLATORY TUBE
Li Xuelai,Guo Rongwei,Fang Yaoqi,Yu Hongru. OF HEAT TRANSFER CONDITIONS ON PERFORMANCE OF OSCILLATORY TUBE[J]. Journal of Chemical Industry and Engineering(China), 2000, 51(1): 12-16
Authors:Li Xuelai  Guo Rongwei  Fang Yaoqi  Yu Hongru
Abstract:The oscillatory tube respresents a simple arrangement for gas cooling by its decompression,and has many applications in chemical processes and energy transformation. The mechanism of the cooling effect of oscillatory tube is the conversion of the pressure energy of gas to heat through the movement of pressure waves,which are moving shock wave and unsteady expansion wave. The radial heat transfer through the tube wall will influence the performance of the oscillatory tube significantly. In the present paper, the effects of heat transfer conditions outside of an oscillatory tube on the performance of the tube are investigated experimentally. In the experiments,two kinds of typical heat transfer conditions,natural convection and forced convection(axially water cooled),are studied. The oscillatory tube is a red copper tube,14 mm in diameter and 4 2 m in length. The pressure ratio is in the range of 2 0—6 0. The ambient temperature is 15 ℃. The inlet temperature of the cooling water is 17 7 ℃ at a flow rate of 0 81 kg·s -1 . The experimental results show that the refrigerating efficiency of the tube is increased by 4 6%—5 4% when the heat transfer condition outside the tube wall is improved by axial water cooling. Also,the optimum pulsing frequency ( f opt ) of the driving jet flow is reduced significantly and the value of f opt is no longer affected greatly by the pressure ratio when the heat transfer outside of the tube is intensified. The theoretical analyses of the experimental results are also presented.
Keywords:heat transfer  oscillatory flow  direct expansion refrigeration  shock wave  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《化工学报》浏览原始摘要信息
点击此处可从《化工学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号