莱芜发电厂 125 MW 机组运行经济性分析 |
| |
引用本文: | 王学栋,何洪宾.莱芜发电厂 125 MW 机组运行经济性分析[J].山东电力技术,1998(1):40-43. |
| |
作者姓名: | 王学栋 何洪宾 |
| |
作者单位: | 山东电力科学研究院,山东莱芜发电总厂 |
| |
摘 要: | 依据2号机修前考核试验结果以及1号、2号、3号机历史试验数据,对三台机组的热耗、高、中、低压缸效率进行了定性和定量的分析,找出了三台机组热耗较高、高、低压缸效率低、中压缸效率高于设计值的原因。
|
关 键 词: | 125MW机组 性能试验 热耗率 |
Economical Analysis of Three Early 125 MW Turbines Installed in Lai wu Power Plant |
| |
Abstract: | Based on the data of performance test before overhaul of NO.2 turbine and the historical experimental data of NO.1、NO.2、NO.3 turbines,The reason of higher heat rate of the three turbines as well as lower efficiency of HP、LP has been analyzed qualitatively and quantitatively in this paper.The reasons why heat rate of the three turbines is higher,why efficiency of HP and LP is lower,and why efficiency of IP is higher than design data have been found. |
| |
Keywords: | 125 MW Unit Performance test Heat rate |
本文献已被 CNKI 维普 等数据库收录! |