首页 | 本学科首页   官方微博 | 高级检索  
     

气体搅拌萃取过氧化氢实验研究
引用本文:张香文,吕树祥,王莅,刘建国,米镇涛.气体搅拌萃取过氧化氢实验研究[J].高校化学工程学报,2006,20(2):192-196.
作者姓名:张香文  吕树祥  王莅  刘建国  米镇涛
作者单位:1. 天津大学,化工学院绿色合成与转化教育部重点实验室,天津,300072
2. 天津大学,化工学院绿色合成与转化教育部重点实验室,天津,300072;天津科技大学,材料科学与化工学院,天津,300222
摘    要:在内径为50 mm的筛板塔内,研究了空气-水-蒽醌工作液三相体系萃取过氧化氢过程.萃取温度为40℃,空气和分散相的表观流速分别为(1.31~3.22)×10-3m·s-1和(1.27~1.70)×10-3 m·s-1,分散相和连续相的表观流速之比为50:1.结果表明,在普通液-液萃取过氧化氢过程中引入气体作搅拌,可减小分散相的液滴直径,增大相际接触面积,明显提高萃取效率,降低萃余相中过氧化氢的含量.传质单元高度随气体表观流速的增加而降低,传质系数随气体表观流速的增加而增大.

关 键 词:过氧化氢  气体搅拌萃取  蒽醌工作液  传质单元高度  传质系数
文章编号:1003-9015(2006)02-0192-05
收稿时间:2004-07-22
修稿时间:2005-03-21

Experimental Investigation of a Gas-Agitated Sieve Plate Column for Hydrogen Peroxide Extraction
ZHANG Xiang-wen,L Shu-xiang,WANG Li,LIU Jian-guo,MI Zhen-tao.Experimental Investigation of a Gas-Agitated Sieve Plate Column for Hydrogen Peroxide Extraction[J].Journal of Chemical Engineering of Chinese Universities,2006,20(2):192-196.
Authors:ZHANG Xiang-wen  L Shu-xiang  WANG Li  LIU Jian-guo  MI Zhen-tao
Affiliation:ZHANG Xiang-wen,L(U) Shu-xiang,WANG Li,LIU Jian-guo,MI Zhen-tao
Abstract:The novel process of extracting hydrogen peroxide from anthraquinone working solution by deionized water in a sieve plate column with bottom gas injection was investigated. Oxidized anthraquinone working solution and deionized water were used as dispersed and continuous phases, respectively. And the air was used as stirred gas, which flows upward cocurrently with dispersed phase. The flow rate ratio of the dispersed and continuous phases was kept at 50:1. The results show that when the extraction process is with gas-agitaion, the concetration of hydrogen peroxide in raffinate phase is obviously lower than that of the conventional liquid- liquid extraction process and the height of transfer unit (HTU) is greatly reduced, which is only 1/2 of that of conventional liquid-liquid extraction column. The mass-transfer coefficient of the hydrogen peroxide from anthraquinone working solution to water in a gas-agitated sieve plate column is about 2 times higher than that of conventional liquid-liquid extraction. This may attribute to the improvements of dispersed phase droplets dispersion and surface renewal, which in turn enhances the mass transfer.
Keywords:hydrogen peroxide  gas-agilated extraction  anthraquinone working solution  height of transfer unit  mass-transfer coefficient
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏