首页 | 本学科首页   官方微博 | 高级检索  
     

风电场集群并网接纳功率极限计算分析
引用本文:刘绎高,徐建源,祝贺.风电场集群并网接纳功率极限计算分析[J].东北电力技术,2011,32(12):3-7.
作者姓名:刘绎高  徐建源  祝贺
作者单位:沈阳工业大学电气工程学院,辽宁 沈阳,110870
摘    要:提出了一种基于静态稳定分析的风电场集群并网接纳功率极限的计算方法.该方法通过计算单风电场并网的接纳功率极限和对应的指标IVQ、IθP,,以此为判定依据求取多风电场集群并网的接纳功率极限.将该方法应用到我国某地区电网,验证了该方法的实用性.

关 键 词:风电场  集群并网  接纳功率极限

Calculation and Analysis on the Limit Power Acceptance of Wind Farm Cluster Grid Integration
LIU Yi-gao , XU Jian-yuan , ZHU He.Calculation and Analysis on the Limit Power Acceptance of Wind Farm Cluster Grid Integration[J].Northeast Electric Power Technology,2011,32(12):3-7.
Authors:LIU Yi-gao  XU Jian-yuan  ZHU He
Affiliation:(School of Electrical Engineering,Shenyang University of Technology,Shenyang,Liaoning 110870,China)
Abstract:An approach to calculate the limit power acceptance of wind farm cluster grid integration based on static stability analysis is presented.Calculating the limit power acceptance of single wind farm and the indicators is recommended in this paper.On this basis,calculate the limit power acceptance of multi-wind farm cluster grid integration.Applying this approach to a gird in certain area in China approves that this approach is practical.