摘    要:水口水力发电厂200MW轴流转桨式水轮机转轮运行中大量进水,停机检查又找不到任何泄漏点。本简要分析了介绍了水口水电厂6号机组转轮进水的原因和查找处理方法。

关 键 词:水电厂  水轮发电机  转轮  进水处理

The Cause and Solved Process of Plenty of Water Flowing into the Runner of Unit 6 at Shuikou Hydroelectric Power Plant
Chen Tejie.The Cause and Solved Process of Plenty of Water Flowing into the Runner of Unit 6 at Shuikou Hydroelectric Power Plant[J].Large Electric Machine and Hydraulic Turbine,1998(4):49-53.
Authors:Chen Tejie
Affiliation:Shuikou Hydroelectric Power Plant
Abstract:Plenty of water had been leaking out into the 200MW ZZA315-LJ-800 Kaplan turbine at Shuikou hydroelectric power plant when the unit 6 was running. However, no leakage could be found after the unit was stopped .The safety operation of the unit was seriously menaced by this ,and it is very difficult to find out the reason .The cause of plenty of water flowing into the runner of unit 6 and solved process at Shuikou hydroelectric power plant were analyzed.