首页 | 本学科首页   官方微博 | 高级检索  
     

用于硼中子俘获治疗的医院中子照射器的反应堆光致缓发中子参数
引用本文:沈峰,吕征,孙志勇,赵守智.用于硼中子俘获治疗的医院中子照射器的反应堆光致缓发中子参数[J].原子能科学技术,2008,42(8):697-701.
作者姓名:沈峰  吕征  孙志勇  赵守智
作者单位:中国原子能科学研究院 ;反应堆工程研究设计所,北京 ; 102413
摘    要:在介绍单群扩散方程基础上,引入堆芯和反射层的中子价值,根据考虑了光致缓发中子及其价值因素的点堆动态方程,建立了利用现有计算程序进行计算和分析的方法,分析了医院中子照射器光致缓发中子的特性参数,在原有6组缓发中子基础上增加了9组光致缓发中子,为进一步进行用于硼中子俘获治疗的医院中子照射器反应堆的点堆动力学研究提供了重要参数。

关 键 词:硼中子俘获治疗    医院中子照射器    光致缓发中子    中子价值
收稿时间:2007-04-10
修稿时间:2007-05-24

Delayed Gamma-induced Neutron Parameters on Reactor Of In-hospital Neutron Irradiator for Boron Neutron Capture Therapy
SHEN Feng,LU Zheng,SUN Zhi-yong,ZHAO Shou-zhi.Delayed Gamma-induced Neutron Parameters on Reactor Of In-hospital Neutron Irradiator for Boron Neutron Capture Therapy[J].Atomic Energy Science and Technology,2008,42(8):697-701.
Authors:SHEN Feng  LU Zheng  SUN Zhi-yong  ZHAO Shou-zhi
Affiliation:China Institute of Atomic Energy, P.O.Box 275-33, Beijing 102413, China
Abstract:n order to analyze the influence on dynamics characteristics from delayed gamma-induced neutron for nuclear reactor of in-hospital neutron irradiator, which used to cure cancer with technology of boron neutron capture therapy (BNCT), the dynamics equation of point-reactor included the quantity, worth and decay constant of gamma-induced neutron was set by introducing neutron worth in reactor core and reflector in the one group diffusion equation. The calculation methods on generation rate of delayed gamma-induced neutron, the worth of neutrons generated from fission reaction or gamma-induced were also introduced. The total numerical calculation methods were studied with help of current calculation software and its sketch was shown. The mentioned parameters were calculated and analyzed for the nuclear reactor of in-hospital neutron irradiator. As a result, parameters of 9 groups delayed neutron were added to normal 〖HJ〗6 groups. The tendency was analyzed and the good coincidence was verified with experiments from other research reactors which consist of beryllium in reactor complex.
Keywords:boron neutron capture therapy  in-hospital neutron irradiator  gamma-induced neutron  neutron worth
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《原子能科学技术》浏览原始摘要信息
点击此处可从《原子能科学技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号