摘    要:OPPC的结构与OPGW雷同,但二者的功能和应用环境有本质区别,目前多用于老线路换线工程,OPPC除了应该满足导线的一切性能外,还应该考虑与原有导线配合。文章以古交变一江湾变35kV输电线路中的大截面OPPC换线工程为例,介绍了OPPC与OPGW的主要区别,提出了OPPC在结构设计时与原有导线配合的原则。

关 键 词:OPPC  OPGW  导线  应力  弧垂

Design and application of 35kV large cross-section OPPC
ZHANG Jian-ming,GAO Xin-zhong,HUANG Jun-hua. Design and application of 35kV large cross-section OPPC[J]. Telecommunications for Electric Power System, 2009, 30(2): 53-57
Authors:ZHANG Jian-ming  GAO Xin-zhong  HUANG Jun-hua
Affiliation:1.Tongguang Group Ltd.;Shanghai 200122;China;2.Shanxi Electric Power Communication Center;Taiyuan 030001;China
Abstract:Although the structure of OPPC is similar to that of OPGW,their function and application environment are quite different.At present,OPPC is mainly used to replace conductors in existing lines.So OPPC must meet all the requirements of conductors.This paper introduces the differences between OPPC and OPGW based on the large cross-section OPPC replacement project of 35kV Gujiaobian-Jiangwanbian power transmission line,and put forward some guide lines for the design of OPPC structure.