基金项目:国家“十二五”科技支撑计划课题项目(2014BAL06B03);国家自然科学基金项目(51208411);中建股份科技研发课题项目(CSCEC-2012-Z-16);西安建筑科技大学创新团队项目
摘    要:为研究传统风格建筑圆钢管柱-箱形截面双梁节点受力性能,对传统风格建筑圆钢管柱-箱形截面双梁中节点和边节点进行低周反复加载试验,分析了双梁-柱节点的破坏特征及影响因素。研究结果表明:传统风格建筑圆钢管柱-箱形截面双梁节点的破坏模式主要是下梁与大柱形成的核心区(3区)发生剪切屈服,上梁、下梁与大柱所形成的区域(2区)发生压弯破坏,部分焊缝及其热影响区的母材开裂;轴压比为0.3试件的极限承载力均高于轴压比为0.6的节点试件;相同轴压比下中节点试件的承载力高于边节点试件。给出了节点核心区2区压弯承载力验算公式并推导了节点核心区3区抗剪承载力计算公式,经与试验结果相比较,吻合较好。

关 键 词:传统风格建筑    圆钢管柱    箱形截面梁    双梁-柱节点    受剪承载力
收稿时间:2015-08-10

EXPERIMENTAL STUDY ON MECHANICAL PERFORMANCE AND STRENGTH PREDICTION OF CIRCLE TUBULAR STEEL COLUMN-DOUBLE BOX-SECTION BEAM JOINTS IN TRADITIONAL STYLE BUILDING
Affiliation:1.School of Civil Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China;2.Northwestern Architectural Design Institute Co. Ltd, Xi'an 710018, China
Abstract:To study the mechanical performance of circle tubular steel column-double box-section beam joints in traditional style building, an experiment of circle tubular steel column-double box-section beam inner joints and edge joints in traditional style building under low cyclic reversed loading was conducted. Failure patterns and influence factors on shear capacity were analyzed. The results indicate that the typical modes of steel traditional style framework double beam-column joints are the shear failures of joint core between lower beam and column (namely Area 3), and the core area between upper beam, lower beam and column (namely Area 2) are buckled, and some welds and their heat-affected areas are cracked. The ultimate bearing capacity of specimens with axial compression ratio of 0.3 is higher than the joints with axial compression ratio of 0.6. At the same axial compression ratio the bearing capacity of the inner joint specimens is higher than that of the edge joints. Formulas for checking the compression-bending capacity of core area 2 and calculating the shear bearing capacity of core area 3 are deduced by mechanical method. The results show that the calculation results agree well with the test results.
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《工程力学》浏览原始摘要信息
点击此处可从《工程力学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号