首页 | 本学科首页   官方微博 | 高级检索  
     

溪洛渡直流工程同杆双回线路电磁环境指标研究
引用本文:赵宇明,路遥,吕金壮,张广洲,黎小林. 溪洛渡直流工程同杆双回线路电磁环境指标研究[J]. 南方电网技术, 2010, 4(6): 61-64
作者姓名:赵宇明  路遥  吕金壮  张广洲  黎小林
作者单位:1. 南方电网科学研究院,广州,510080
2. 国家电网电力科学研究院,武汉,430074
摘    要:同杆双回直流线路的电磁环境指标比起单回直流线路要复杂得多。文章根据溪洛渡直流工程选定的导线截面参数(4×900分裂导线)和运行电压(±500 kV),研究了同杆双回直流线路在不同极导线排列方式下各项电磁环境指标的变化规律。结果表明,由于导线截面较大,该工程线路无论采用何种极导线排列方式均能满足电磁环境限值要求,因此,电磁环境指标不是决定该工程极导线布置方式的决定性因素。

关 键 词:直流线路  同杆双回  电磁环境
收稿时间:2010-04-06

Study on the Electromagnetic Environment Index of DoubleCircuit Transmission Lines on the Same Tower in Xiluodu HVDC Project
ZHAO Yuming,LU Yao,LV Jinzhuang,ZHANG Guangzhou and LI Xiaolin. Study on the Electromagnetic Environment Index of DoubleCircuit Transmission Lines on the Same Tower in Xiluodu HVDC Project[J]. Southern Power System Technology, 2010, 4(6): 61-64
Authors:ZHAO Yuming  LU Yao  LV Jinzhuang  ZHANG Guangzhou  LI Xiaolin
Affiliation:Electric Power Research Institute, CSG, Guangzhou 510080, China;State Grid Electric Power Research Institute, Wuhan 430074, China;Electric Power Research Institute, CSG, Guangzhou 510080, China;State Grid Electric Power Research Institute, Wuhan 430074, China;Electric Power Research Institute, CSG, Guangzhou 510080, China
Abstract:The electromagnetic environment of doublecircuit HVDC transmission line is more complex than that of the singlecircuit one. According to the conductor parameters, which are of the 4 × 900 conductor, and the operation voltage of ±500 kV selected for Xiluodu HVDC project, this paper calculates the electromagnetic environment index of the line under the conditions of various poleline arrangements on the same tower. The results show that the doublecircuit transmission lines could meet the electromagneticlimitvalue requirement under each poleline arrangement as the selected conductor has a cross section large enough. Therefore, the electromagnetic environmnet index is not a decisive factor for the poleline arrangement of the project.
Keywords:HVDC transmission line   double circuits on the same tower, electromagnetic environment
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《南方电网技术》浏览原始摘要信息
点击此处可从《南方电网技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏