郑州某超高层酒店生活热水系统改造案例分析
作者姓名:任天宇
作者单位:上海东方低碳科技产业股份有限公司
摘    要:以郑州某超高层酒店生活热水系统改造为例,对酒店锅炉系统进行能源流向分析。考虑到系统冷热同源问题,不同热水分区设定不同的改造方案,同时确定各个分区详细的设备参数配置及节能量分析计算。对超高层酒店生活热水系统改造后,蒸汽锅炉系统综合节能率达28.4%,可为同类建筑热水系统改造提供借鉴。

关 键 词:超高层  生活热水  节能改造  风冷热泵  水水热泵

Case Analysis of Super High-Rise Hotel Domestic Hot Water System Renovation in Zhengzhou
Authors:REN Tianyu
Affiliation:(Shanghai East Low Carbon Technology Industry Co.,Ltd.)
Abstract:Taking a super high-rise hotel domestic hot water system transformation in zhengzhou as an example.This paper analyzes the energy flow of the boiler system,considering the same source of cold and heat water in the system,different transformation schemes are set for different hot water zones,meanwhile detailed equipment parameter configuration and energy saving analysis are determined for each zone.Through the case analysis of a super high-rise hotel domestic hot water system transformation,the comprehensive energy saving rate of steam boiler system reaches 28.4%,which can provide reference for the transformation of hot water system in similar buildings.
Keywords:Super High-Rise  Domestic Hot Water  Energy Saving Renovation  Air-Cooled Heat Pump  Water-Water Heat Pump