首页 | 本学科首页   官方微博 | 高级检索  
     

喷水减温对热经济性的影响分析
引用本文:张树芳,臧与佳. 喷水减温对热经济性的影响分析[J]. 节能, 2011, 30(3): 27-29. DOI: 10.3969/j.issn.1004-7948.2011.03.007
作者姓名:张树芳  臧与佳
作者单位:华北电力大学,热能与动力学院,河北,保定,071003
摘    要:给出通用型系统热经济性方程,并针对国产300MW机组,分析了过热器、再热器不同喷水位置对其热经济性的影响。结果表明,无论是过热器还是再热器,其减温水从最高加热器出口分流的影响较小,而再热器喷水对机组经济性的影响远大于过热器。

关 键 词:气温调节  状态方程  经济性

The analysis on the impacts of the unit economical efficiency about spraying desuperheating
ZHANG Shu-fang,ZANG Yu-jia. The analysis on the impacts of the unit economical efficiency about spraying desuperheating[J]. Energy Conservation, 2011, 30(3): 27-29. DOI: 10.3969/j.issn.1004-7948.2011.03.007
Authors:ZHANG Shu-fang  ZANG Yu-jia
Affiliation:ZHANG Shu-fang,ZANG Yu-jia(North China Electric Power University,School of Energy and Power Engineering,Baoding 071003,China)
Abstract:Gives the universal thermo economic equation,analysised the influences on the thermo economics of the unit caused by different spray positions of superheater and reheater based on domestic 300MW unit.The result shows that,attemperating water discharged from the highest heater of superheater and reheater has the least influence.And the water from reheater has a larger effect on thermo economics of the unit than the water from superheater.
Keywords:regulation of steam temperature  state equation  economical efficiency  
本文献已被 CNKI 维普 万方数据 等数据库收录!