A thermal neutron mini-detector with SiPM and scintillating fibers |
| |
Authors: | M. Barbagallo,L. CosentinoG. Greco,G. GuardoR.M. Montereali,A. PappalardoC. Scirè ,S. Scirè ,M.A. VincentiP. Finocchiaro |
| |
Affiliation: | a INFN Laboratori Nazionali del Sud, via S.Sofia 62, 95125 Catania, Italy b Ansaldo Nucleare S.p.A., corso Perrone 25, 16161 Genova, Italy c ENEA C.R. Frascati, via Enrico Fermi 45, 00044 Frascati (Roma), Italy |
| |
Abstract: | We developed and tested a simple prototype of thermal neutron detector suitable for inexpensive deployment in the decommissioning and storage of radioactive waste, as well as for mapping the flux in the out-of-core regions of fission reactors. Though the prototype version we tested provides the neutron rate by subtracting the gamma background measured with a twin detector insensitive to neutrons, a simple geometrical improvement can strongly reduce the gamma contribution. |
| |
Keywords: | Thermal neutrons Neutron converter Silicon Photomultiplier Scintillators |
本文献已被 ScienceDirect 等数据库收录! |
|