首页 | 本学科首页   官方微博 | 高级检索  
     


Consideration of bank storage when determining the power output of a hydroelectric station
Authors:Aleksandrovskii  A Yu  Litvin  N K
Abstract:
1.  The interaction of surface and subsurface waters increasing streamflow regulation is not taken into account in the practice of designing hydrostations.
2.  The proposed method of taking it into account, realized in the form of a program of calculations with the use of computers, makes it possible to estimate the effect of the indicated factor on any planned hydropower facility.
3.  A preliminary evaluation of taking into account the effect of the interaction of surface and subsurface waters for the example of a hydrostation with a seasonal reservoir made it possible to estimate it with respect to an increase of firm capacity within 0.4–0.9% and with respect to an increase of useful storage of the reservoir within 3–6%. This refinement should be added to the margin of safety of the power indices of the planned hydrostation.
Translated from Gidrotekhnicheskoe Stroitel'stvo, No. 2, pp. 14–16, February, 1988.