摘    要:通过对分支回路的线路过负荷、连接不良和谐波等电气火灾主要成因的分析,结合国内外电气防火规范,以及实际工程中使用的工艺、装置及检验仪表的具体情况,对分支回路的施工、验收、维修、维护提出建议,强调借助适当的预防性检测器具,提高用电安全性。

关 键 词:电气防火  金属性短路  电弧性短路  接地故障  连接不良  导线连接器  检测器具

Preventive Detection of Electrical Fire in Branch Circuit
Ren Changning.Preventive Detection of Electrical Fire in Branch Circuit[J].Building Electricity,2011,30(1):31-36.
Authors:Ren Changning
Affiliation:Ren Changning(IDEAL INDUSTRIES,Inc. Beijing Office,Beijing 100738,China)
Abstract:Through the analysis of the major causes of electrical fires in branch circuit,i. e.,circuit overload,poor connections and harmonics,combined with electrical fireproofing codes at home and abroad,and the specific circumstances of the processes,apparatus and inspection instruments used in practical engineering,the recommendations have been put forward in construction,acceptance,repair and maintenance of the branch circuit,emphasizing the use of appropriate preventive detection equipments to improve power uti...