首页 | 本学科首页   官方微博 | 高级检索  
     

Simulation of Lightning Overvoltage Distribution on Stator Windings of Wind Turbine GeneratorsEI北大核心CSCD
作者单位:1.State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an J iaotong University, Xi'an 710049, China;
基金项目:Project Supported by National Natural Science Foundation of China(50877063)
摘    要:This paper analyzes lightning surge on the stator windings of wind turbine generators. The path of lightning in the wind turbines was analyzed. An equivalent circuit model for megawatt direct-driven wi...


Simulation of Lightning Overvoltage Distribution on Stator Windings of Wind Turbine Generators
LIU Rong , LIU Xue-zhong , WANG Ying , LI Dan-dan. Simulation of Lightning Overvoltage Distribution on Stator Windings of Wind Turbine Generators[J]. High Voltage Engineering, 2011, 37(11): 2680-2685
Authors:LIU Rong    LIU Xue-zhong    WANG Ying    LI Dan-dan
Affiliation:State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an J iaotong University, Xi'an 710049, China
Abstract:This paper analyzes lightning surge on the stator windings of wind turbine generators. The path of lightning in the wind turbines was analyzed. An equivalent circuit model for megawatt direct-driven wind turbine system was developed, in which high-frequency distributed parameters of the blade conducts, tower, power cables and stator windings of generator were calculated based on finite element method, and the models of converter, grounding, loads, surge protection devices and power grid were established. The voltage distribution along stator windings, when struck by lightning with 10/350 ~ts wave form and different amplitude current between 50 kA and 200 kA, was simulated u- sing electro-magnetic transient analysis method. The simulated results show that the highest coil-to-core voltage peak appears on the last coil or near the neutral of stator windings, and the voltage distribution along the windings is non- uniform initially. The voltage drops of each coil fall from first to last coil, and the highest voltage drop appears on the first coil. The insulation damage may occur on the windings under lightning overvoltage. The surge arresters can re- strain the lightning surge in effect and protect the insulation. The coil-to-core voltage in the end of windings is nearly 19.5 kV under the 200 kA lightning current without surge arresters on the terminal of generator, but is only 2.7 kV with arresters.
Keywords:equivalent circuit  lightning  overvoltage  stator windings  simulation  wind turbine generator