摘    要:An online partial discharge (PD) measurement performed on a high voltage direct current (HVDC) wall bushing successfully identified the presence of internal discharges. The wall bushing is a sulfur hexafluoride gas-insu- lated bushing, rated for 500 kV dc and terminated on a thyristor-controlled HVDC converter bridge. The measure- ment of PD within the HVDC station environment is particularly challenging due to the high levels of electromagnetic noise caused by thyristor switching events and external air-corona from the neighboring high-voltage equipment. An additional challenge is the "mixed" voltage stress on the bushing insulation, which has both ac and dc high-voltage components. There are also fast transients during the firing of thyristors in the HVDC conversion process that cause added stress to the insulation. As a result, the analysis and interpretation of PD data for HVDC equipment is more complex; PD pulses may occur in response to the ac, dc, or switching transient voltage stresses. In this paper, an on- line PD measurement strategy for noise filtering and isolation of PD sources within the bushing are discussed. The PD measurement data is plotted on a phase-resolved diagram where the line supply power cord voltage was used as a reference. The phase-resolved diagram appears to suggest that the fast transients, caused during switching, trigger some PD events. Measurements were also performed with the aid of a modern PD measurement instrument having noise separation capabilities. The findings from the online PD measurements are verified with physical evidence, found after the bushing was removed from service, suggested internal PD had occurred inside the bushing.

关 键 词:partial discharge(PD)  electrical insulation  high voltage direct current(HVDC) converters  SF6  electro- magnetic interference  electromagnetic coupling

Online Partial Discharge Measurement of a High-voltage Direct Current Converter Wall-bushing
Nathan D. Jacob , William M. McDermid , Behzad Kordi. Online Partial Discharge Measurement of a High-voltage Direct Current Converter Wall-bushing[J]. High Voltage Engineering, 2011, 37(11): 2636-2642
Authors:Nathan D. Jacob    William M. McDermid    Behzad Kordi
Abstract:
Keywords:partial discharge(PD)  electrical insulation  high voltage direct current(HVDC) converters  SF6  electro- magnetic interference  electromagnetic coupling